Onbadhu roobai not turning hd movie downloads Dec 25, 2018 - Tagged: manual, meat, n2000, server, Snap. 2018 2012 movie zedna tronic cbt 0201 manual meat de bremraap OS Support: Windows 2000.

• Control Panel User Manual Version: 1.2 Date: Jan., 2014 About This Manual This manual introduces C3-100/200/400 access control panel installation connection and user manual. • Contents Contents 1 Important Security Instructions.- 1 - 1.1 Important Security Instructions.- 1 - 1.2 Installation Cautions.- 3 - 2 Introduction..- 5 - 2.1 System Function Parameters.- 5 - 2.2 Product Technical Parameters.- 5 - 2.3 Control Operator Panel Indicators.- 7 - 3 Connection and Installation.- 8 - 3.1 Case Installation.- 8 - 3.2 Installation of Access Control Operator Panel Wires.- 9.

• Important Security Instructions 1 Important Security Instructions 1.1 Important Security Instructions Read, follow and keep instructions: Before operating the equipment, read and follow strictly all security and operation instructions. Please keep the instructions in good condition for future reference. Accessories: Please use the accessories recommended by the manufacturer or delivered with the product. • Control Panel User Manual If the equipment cannot work normally even though operated as instructed, please be sure to adjust only the control components specified in the operation instructions. Incorrect adjustment of other control components may cause damage to the equipment, and add to troubleshooting workload of the qualified technicians.

• Important Security Instructions 1.2 Installation Cautions The conduits of wires under relay must be matched with metaled conduits, other wires can use PVC conduits, to prevent failure caused by rodent damage. Although a control panel is designed with good antistatic, lightning-proof, and leakage-proof functions, ensure its chassis and the AC ground wire are connected properly and the AC ground wire is grounded physically. • Control Panel User Manual Get prepared countermeasures according to application scenarios for unexpected power failure, like selecting power supply with UPS. The connection between a card reader and a control panel should not be longer than 100m. The connection between a PC and a control panel should be shorter than 1200m for RS485 communications. • Introduction 2 Introduction The access control management system is a new modernized security management system, which is an effective measure for security and protection management. It is mainly used to manage entrances and exits of important places, such as banks, hotels, equipment rooms, offices, smart communities, and factories.

• With detachable connection terminals made of alloy-steel non-magnetic flange materials. Outline dimensions of the control PCB: 160mm (length) × 106mm (width) for C3-100/200; 216mm (length) × 106mm (width) for C3-400. External box dimensions: 360mm × 285mm × 75mm. Valve regulated lead-acid battery: Constant voltage charge voltage regulation Cycle use: 14.5V~14.9V(25) • Introduction 2.3 Control Operator Panel Indicators When the C3-100/200/400 is powered on, normally the POWER indicator (red) is lit constantly, the RUN indicator (green) flashes (indicating the system is normal), and other indicators are all off. Except the cases as follows: LINK indicator (green): indicates proper TCP/IP connection if it is lit constantly. • Control Panel User Manual 3 Connection and Installation 3.1 Case Installation - 8.

• Connection and Installation 3.2 Installation of Access Control Operator Panel Wires 220V input RS485 network TCP/IP network communication wire communication wire C3 access control operator panel Ceiling Door sensor Electronic lock Exit button Outdoor Wiegand Indoor Wiegand card reader card reader Indoor Outdoor Figure 3-1 Access Control Operator Panel Wire Installation Diagram. • Figure 3-2 Schematic Diagram of C3-400 System Installation Note: The diagram above takes the C3-400 for example.

By contrast, only one-door two-way access is applicable to the C3-100 system; only two-door one-way or two-door two-way access is applicable to the C3-200 system. • Connection and Installation The access control management system consists of two parts: management workstation (PC) and control operator panel. They communicate via TCP/IP and RS485 networks. On a 485 bus, each management workstation can be connected with up to 63 C3 control operator panels (preferably fewer than 32).

Zedna tronic cbt 0201 manual artsy

The communication wires should be kept away from high-voltage wires as far as possible, and should be neither routed in parallel with nor bundled with power wires. • Control Panel User Manual 3.4 Control Operator Panel Connection Terminals C3-100 terminal connection diagram - 12.